Process:
 

Inserting Multi-section shunting signal at Signal Brackets using example 60F and 60FF.

 

 

Requirements:
 

see Signals - EPU

 

Description:

Using the examples 60F and 60FF, the procedure for inserting multi-section shunting signals at Signal Brackets is explained step by step.

 

First, signal 60F with the Signal aspects Zs 7, Zs 3 and Zs 3v and a mounting type 'Signalanordnung Arbeitsbühne' is inserted on track 22. For the signal, a second mounting of the type 'Signalausleger' is created. Signal 60FF with the Signal aspects Zs 7 and Zs 3v and a mounting type 'Signalanordnung Arbeitsbühne' is then inserted on track 21. The Signal 60FF is assigned as the second mounting to the 'Signalausleger' mounting of the first signal.

 

It is described to which attributes have to be edited in order to ensure a correct view in the drawing and (at a later time) a complete export.

 

Procedure:
 

1.To generate the first signal at the bracket, use the 'New' (D) button to insert a new signal, as described under Insertion of Signals. To edit this example, select the Signal type 'Leer'.

 

bsp_60F_60FF_schritt1_ppt
Illus.: Newly Inserted Signal

 
 

oWhen inserting, select a point on the first topological edge.
 

oThe Signal is generated with a Signal mount (B) ('Mounting type' (C) = 'Signalanordnung Mast') and an empty Signal frame (D) ('Frame type' (E) = 'Schirm').

 

 

2.In the section Signal (F), the following attributes have to be edited:

 

Nr.

Attribute

Value

1

Local element identifier

F

2

Befestigungsart

Signalausleger

3

Schirm: Bedienart

Wb/zb

4

Schirm: Art  

Mehrabschnittssignal

5

Aktiv: Funktion

Einfahrsignal

6

Aktiv: Information

P-Hausen (Objekt Außenelementansteuerung)

7

Aktiv: Energie

P-Hausen (Objekt Außenelementansteuerung)

8

Schirm: Dunkelschaltung

nein (Strich)

9

Schirm: Richtpunktentfernung

450

10

Schirm: Signalsystem

Ks

11

Aktiv: Signalsicht Erreichbar

500

12

Aktiv: Signalsicht Mindest

300

13

Aktiv: Signalsicht Soll

500

14

Schirm: Streuscheibe

HG

15

Schirm: Betriebsstellung

HG2

 Table: Attributes to be edited for the first Signal on the Bracket

 

bsp_60F_60FF_schritt3-7_ppt

Illus.: Editing the automatically generated Objects Signal mount, Signal frame and Signal aspect for Signal 60F on the Bracket

 

 

After changing the attribute 'Schirm: Art' (G), the corresponding Signal aspects are automatically created.

 

 

oThe Signal aspect of the main screen ('Signal aspect ID' = 'Hp_0' (K), 'Ks_1' (L) and 'Ks_2' (M)) are assigned to the Signal frame with the 'Frame type' = 'Schirm' (H).

 

oFor the Signal type indicators ('Signal aspect ID' = 'Ms_ge_D' (O) and 'Ms_ws_rt_ws' (P)) separate Signal frames with the 'Frame type' = 'Blechtafel' (I, J) are created. Each Signal frame 'Blechtafel' is assigned a Signal aspect object with the corresponding Signal aspect ID.

 

 

3.For the automatically created Signal mounting (Q) the following attributes have to be edited:

 

Nr.

Attribute

Value

1

Standard drawing

S 8130.13.2, LP= 7650 (Objekt Regelzeichnung)

2

Mounting type

Signalanordnung Arbeitsbühne

3

Obere Lichtpunkthöhe

7.650 (Angabe in Metern, Dezimaltrenner ".")

 Table: Attributes to be edited for the Signal mounting of the Signal 60F

 

 

4.In order to define the switch-ability of the Signal aspects for the screen, after marking the Signal frame 'Schirm' (H) in the section 'Signal aspect' (R) for the assigned Signal aspects the following attributes have to be edited:

 

Nr.

Signal aspect ID

Switched

Lighted

Activation time

Signal symbol

1

Hp_0

leer

ja

G

leer

2

Ks_1

leer

ja

T

leer

3

Ks_2

leer

ja

T

leer

 Table: Attributes to be edited for the existing Signal aspects of the Signal frame Screen

 

 

5.For the marked Signal aspect 'Schirm' (H) in the section 'Signal aspect' (R), with the button 'New' (S) additionally the Signal aspect for the Vorsichtsignal (N) can be created:

 

Nr.

Signal aspect ID

Switched

Lighted

Activation time

Signal symbol

1

Zs_7

leer

ja

90_s

leer

 Table: Signal aspect to be created for the Signal frame Screen

 

 

6.After marking a Signal frame 'Blechtafel' (I, J) in the section 'Signal aspect' (R) the following attributes have to be edited one after the other for the assigned Signal aspect (O, P):

 

Nr.

Signal aspect ID

Switched

Lighted

Activation time

Signal symbol

1

Ms_ws_rt_ws

leer

leer

leer

leer

2

Ms_ge_D

leer

leer

leer

leer

 Table: Attributes to be edited for the Signal frame Metal board (Signal type indicator)

 

 

7.To create a new Signal frame for the Bezeichnungsschild (V), first mark the signal mounting with the Mounting type = 'Signalanordnung Arbeitsbühne' (T). Then create a new signal frame with the button 'New' (Y) in the section 'Signal frame'.

 

bsp_60F_60FF_schritt8-12_ppt  

Illus.: Editing the attributes for Designation plate, Speed indicator at signal and Pre-speed announcer at signal 60F

 

 

Nr.

Attribute

Value

1

Frame type

Bezeichnungsschild

Table: Attribute to be edited for the newly created Signal frame Designation plate

 

oFor the Bezeichnungsschild (V), no signal aspects are created.

 

 

8.To Plan the Zs 3 on signal 60F (Z), first mark the signal mounting (T) with the 'Mounting type' = 'Signalanordnung Arbeitsbühne'. Then create a new signal frame (W) in the section Signal frame with the button 'New' (Y). The following attribute needs to be adjusted:

 

Nr.

Attribute

Value

1

Frame type

Zusatzanzeiger

 Table: Attribute to be edited for the newly created Signal frame

 

 

9.After marking the new Signal frame 'Zusatzanzeiger' (W) in the section Signal frame, the button 'New' (S) is used to create the following Signal aspect for Zs 3 (Z):

 

Nr.

Signal aspect ID

Switched

Lighted

Activation time

Signal symbol

1

Zs_3

nicht beleuchtet

ja

T

6

Table: Signal aspect to be created for the Signal frame Auxiliary indicator (Zs3)

 

 

10.To Plan the Zs 3v on signal 60F (AA, AB, AC, AD), first mark the Signal mount (T) with the 'Mounting type'. Then create a new signal frame (X) in the section Signal frame with the button 'New' (Y). The following attribute needs to be adjusted:

 

Nr.

Attribute

Value

1

Frame type

Zusatzanzeiger

Table: Attributes to be edited for the newly created Signal frame

 

 

11.After marking the new Signal frame 'Zusatzanzeiger' (W) in the section Signal frame, the button 'New' (S) is used to create the following Signal aspect for Zs 3v one after the other (AA, AB, AC, AD):

 

Nr.

Signal aspect ID

Switched

Lighted

Activation time

Signal symbol

1

Zs_3v

nicht beleuchtet

ja

T

4

2

Zs_3v

nicht beleuchtet

ja

T

5

3

Zs_3v

nicht beleuchtet

ja

T

8

4

Zs_3v

nicht beleuchtet

ja

T

12

Table: Signal aspects to be created for the Signal frame Auxiliary indicator (Zs3v)

 

 

12.To create a Signal bracket, first mark the Signal mount 'Signalanordnung Arbeitsbühne' (AG). Then a new Signal mount for the Signal bracket (AH) is created using the button 'New' (AF).

 

bsp_60F_60FF_schritt13-14_ppt

Illus.: Applying the Signal bracket for 60F

 

 

The following attributes have to be adjusted:

 

Nr.

Attribute

Value

1

Mounting type

Signalausleger

2

Standard drawing

S 8000.6.2 (Objekt Regelzeichnung)

Table: Attributes to be edited for the newly created Signal mount Signal bracket

 

 

13.The button 'New' (AE) is used to create the second signal which has to be displayed on the bracket. The procedure for inserting signals is described under Insertion of Signals.

 

oWhen inserting, a point on the second topological edge is selected for which the driving instructions of the signals on the bracket should apply.

 

oThe Signal is created with a Signal mount ('Mounting type' = 'Signalanordnung Mast') and an empty Signal frame ('Frame type' = 'Schirm') (see Step 1).

 

 

14.In the section 'Signal' (AI), the following attributes have to be edited:

 

Nr.

Attribute

Value

1

Local element identifier

FF

2

Befestigungsart

Signalausleger

3

Schirm: Bedienart

Wb/zb

4

Schirm: Art  

Mehrabschnittssignal

5

Aktiv: Funktion

Einfahrsignal

6

Aktiv: Information

P-Hausen (Objekt Außenelementansteuerung)

7

Aktiv: Energie

P-Hausen (Objekt Außenelementansteuerung)

8

Schirm: Dunkelschaltung

nein (Strich)

9

Schirm: Richtpunktentfernung

450

10

Schirm: Signalsystem

Ks

11

Aktiv: Signalsicht Erreichbar

500

12

Aktiv: Signalsicht Mindest

188

13

Aktiv: Signalsicht Soll

500

14

Schirm: Streuscheibe

HG

15

Schirm: Betriebsstellung

HG2

 Table: Attributes to be edited for the second Signal on the Bracket

 

bsp_60F_60FF_schritt15-19_ppt

Illus.: Editing the automatically generated objects Signal mounting, Signal frame and Signal aspect for the Signal 60FF on the bracket

 

 

After changing the attribute 'Schirm: Art' (AK), the corresponding Signal aspects are automatically created.

 

 

oThe Signal aspect of the main screen ('Signal aspect ID' = 'Hp_0' (AP), 'Ks_1' (AQ) and 'Ks_2' (AR)) are assigned to the Signal frame with the Frame type 'Schirm' (AK).

 

oFor the Signal type indicators ('Signal aspect ID' = 'Ms_ws_rt_ws' (AU) and 'Ms_ge_D' (AT)) separate Signal frames with the Frame type 'Blechtafel' (AN, AO) are created. To each Signal frame 'Blechtafel' a Signal aspect object with the corresponding Signal aspect ID is assigned.

 

 

15.For the automatically created Signal mount (AJ), the following attributes have to be edited:

 

Nr.

Attribute

Value

1

Standard drawing

S 8130.13.2, LP= 7650 (Objekt Regelzeichnung)

2

Mounting type

Signalanordnung Arbeitsbühne

3

Obere Lichtpunkthöhe

7.650 (Angabe in Metern, Dezimaltrenner ".")

Table: Attributes to be edited for the Signal mount

 

 

16.In order to determine the switch-ability of the Signal aspects of the screen, after marking the Signal frame 'Schirm' (AM) in the section 'Signal aspect' the following attributes have to be edited for the assigned Signal aspects (AP, AQ, AR):

 

Nr.

Signal aspect ID

Switched

Lighted

Anschaltdauer

Signalsymbol

1

Hp_0

leer

ja

G

leer

2

Ks_1

leer

ja

T

leer

3

Ks_2

leer

ja

T

leer

Table: Attributes to be edited for the existing Signal aspects of the Signal frame Screen

 

 

17.For the marked Signal frame 'Schirm' (AM), in the section 'Signal aspect' with the button 'New' (AV), the Signal aspect for the Substitute signal (AS) should also be created:

 

Nr.

Signalbegriff ID

Geschaltet

Anschaltdauer

Beleuchtet

1

Zs_7

ja

90_s

leer

Table: Signal aspect to be created for the Signal frame Screen

 

 

18.Select the Signal frame 'Blechtafel' (AN, AO) one after the other and edit the following attributes in the section 'Signal aspect' for the respectively assigned Signal aspect (AT, AU):

 

Nr.

Signalbegriff ID

Beleuchtet

Geschaltet

Anschaltdauer

Signalsymbol

1

Ms_ws_rt_ws

leer

leer

leer

leer

2

Ms_ge_D

leer

leer

leer

leer

Table: Attributes to be edited for the Signal frame Metal board (Signal type indicator)

 
 

19.To create a new Signal frame for the Bezeichnungsschild (AX), first mark the Signal mount with the Mounting type = 'Signalanordnung Arbeitsbühne' (AW). Then create a new Signal frame with the button 'New' (AZ) in the section 'Signal frame'.

 

bsp_60F_60FF_schritt20-22_ppt

Illus.: Editing the attributes for Designation plate and Pre-speed announcer at signal 60FF

 

 

Nr.

Attribute

Value

1

Frame type

Bezeichnungsschild

Table: Attribute to be edited for the newly created Signal frame Designation plate

 

oFor the Bezeichnungsschild (AX), no signal aspects are created.

 

 

20.To Plan the Zs 3v on signal 60FF (BA, BB), first mark the Signal mount with the Mounting type = 'Signalanordnung Arbeitsbühne' (AW). Then create a new Signal frame (AY) with the button 'New' (AZ) in the section 'Signal frame'. The following attribute needs to be edited:

 

Nr.

Attribute

Value

1

Frame type

Zusatzanzeiger

Table: Attribute to be edited for the newly created Signal frame

 

 

21.After marking the new Signal frame 'Zusatzanzeiger' (AY) in the section 'Signal frame', the button 'New' (BC) is used to create the following Signal aspect for Zs 3v one after the other (BA, BB):

 

Nr.

Signal aspect ID

Switched

Lighted

Activation time

Signal symbol

1

Zs_3v

nicht beleuchtet

ja

T

4

2

Zs_3v

nicht beleuchtet

ja

T

5

Table: Signal aspects to be created for the Signal frame Auxiliary indicator (Zs3v)

 

 

22.To attach the signal 60FF to the Signal bracket, first mark the signal mounting 'Signalanordnung Arbeitsbühne' (BD). Then the button 'Assign existing mount' (BF) is used to assign the existing signal mount 'Signalausleger' (BE) to signal 60F.

 

bsp_60F_60FF_schritt23_ppt

Illus.: Assignment of the existing Signal bracket of Signal 60F as Signal mounting for Signal 60FF

 
 

oAfter pressing the button, the object selection is started in the drawing.

 

o'Befestigung wählen:' - Select the existing Signal bracket in the drawing which has already cleared for Signal 60F.

 

 

23.The button 'Close' (BG) will close the dialog and the two Signals at the bracket are displayed in the drawing.

 

Bsp_60F_60FF_DWG

Illus.: Signals 60F and 60FF at the Signal bracket in the drawing